SA30520201 EXTRAORDINATOR for crude fibre determination 3 place FIWE 3
This unit allows the extraction of sugars, proteins, fats, mineral salts, lignins, cellulose, hemicellulose, pectins and analogous products in three samples simultaneously. Hot and cold extraction is used. The extractor is equipped with:
- Air pump for mixing samples
- Peristaltic pump for removal of reagent residues and rinse water
- Timer with acoustic signal
- Separate dosing of cooling water and reagents.
Complete with
Thermal screen, PVC hose, glass sintered glassware, model RC2 2-site hotplate, reagent bottles, tongs, three-reagent holder and operating/methods manual.
Additional equipment
A00000140 Glass dishes with sintered glass (6 pieces)
SA30520200 EXTRACTOR for crude fibre determination 6 place FIWE 6
This unit allows the extraction of sugars, proteins, fats, mineral salts, lignins, cellulose, hemicellulose, pectins and analogous products in six samples simultaneously. Hot and cold extraction is used. The extractor is equipped with:
- Air pump for mixing samples
- Peristaltic pump for removal of reagent residues and rinse water
- Timer with acoustic signal
- Separate dosing of cooling water and reagents.
Complete with
Thermal screen, PVC hose, glass sintered vessels, model RC2 2-site heating plate, reagent bottles, tongs, holder for six vessels and operating/methods manual.
Additional equipment
A00000140 Glass dishes with sintered glass (6 pieces)
F30520204 COEX EXTRACTOR
Six-place Rapid Cold Extraction Apparatus designed to accelerate and optimise the initial phase of crude fibre determination in samples containing more than 1% fat.
SA30400209 ENZYME DIGESTER GDE
The reactor is designed to perform hydrolysis prior to the determination of total fibre by enzymatic assay according to the AOAC method. The thermostated unit consists of a heating bath, a transparent vessel, and a 6-site magnetic stirrer. This allows precise temperature control during enzymatic digestion.
F30420210 FILTRATION SYSTEM FOR THE DETERMINATION OF TOTAL FIBRE IN FOOD CSF 6
Six-place Filtration System for the determination of total fibre in food and feed products with an electronically adjustable pressure gauge. This apparatus significantly speeds up and facilitates the filtration process while increasing the repeatability of results in the analysis of bran, food, feed, cereal crops, etc. AOAC-compliant method.
Complete with
6 dishes and instructions for use
F30300240 EXTRAKTOR 3 seater model SER 148/3
3-site apparatus for selective extraction of solid and semi-liquid samples using the Randall technique. Significant reduction in extraction time and solvent recovery is achieved. Reduction in extraction time from 20 to 80%. Solvent recovery from 50 to 70%.
Complete with
Extraction cups, extraction thimble holders, viton and butyl seals, pack of extraction thimbles (25 pieces), operating instructions.
Additional equipment
A00000142 Glass extraction cups, 6 per pack
A00000295 Extraction thimbles, 33 x 80 mm, 25 pieces per pack.
F30300242 EXTRAKTOR 6 seater model SER 148/6
6 site apparatus for selective extraction of solid and semi-liquid samples using the Randall technique. Significant reduction in extraction time and solvent recovery is achieved. Reduction in extraction time from 20 to 80%. Solvent recovery from 50 to 70%.
Complete with
Extraction cups, extraction thimble holders, viton and butyl seals, pack of extraction thimbles (25 pieces), operating instructions.
Additional equipment
A00000142 Glass extraction cups, 6 per pack
A00001145 Extraction cup holder, six-seater
A00000295 Extraction thimbles, 33 x 80 mm, 25 per pack
A00000311 Extraction thimble stand, six-seater.
S303A0390 AUTOMATIC EXTRACTOR 3-seater with controller SER 158/3
3-site apparatus for the automatic selective extraction of solid and semi-liquid samples using the Randall technique. A significant reduction in extraction time and solvent recovery is achieved. Reduction in extraction time. Solvent recovery above 90%.
Complete with
Controller, grey and green gaskets 3 each, extraction cups, extraction cup holder, extraction thimbles 25 boiling stones, reagent bottles and operating/method manual.
Additional equipment
A00000290 Extraction cups Ø 56x120mm, pack of 3 pcs.
A00000295 Extraction thimbles, 33 x 80 mm, 25 per pack
A00000305 Boiling stones, 80 g
A00000312 Extraction thimble holder Ø 33mm
S303A0380 AUTOMATIC EXTRACTOR 6-seater with controller SER 158/6
A 6-site apparatus for the automatic selective extraction of solid and semi-liquid samples using the Randall technique. A significant reduction in extraction time and solvent recovery is achieved. Reduction in extraction time. Solvent recovery greater than 90%.
Complete with
Controller, grey and green gaskets 3 each, extraction cups, extraction cup holder, extraction thimbles 25 boiling stones, reagent bottles and operating/method manual.
Additional equipment
A00000290 Extraction cups Ø 56x120mm, pack of 3 pcs.
A00000295 Extraction thimbles, 33 x 80 mm, 25 per pack
A00000305 Boiling stones, 80 g
A00000312 Extraction thimble holder Ø 33mm
A00000311 Extraction thimble stand, six-seater
F303A0390 AUTOMATIC EXTRAORDINATOR 3 seater without controller model SER 158/3
3-site apparatus for the automatic selective extraction of solid and semi-liquid samples using the Randall technique. A significant reduction in extraction time and solvent recovery is achieved. Reduction in extraction time. Solvent recovery above 90%.
Complete with
Grey and green gaskets 3 each, extraction cups, extraction cup holder, extraction thimbles 25 each, boiling stones, reagent bottles and operating/methods manual.
F303A0380 EXTRAKTOR 6 seater without controller model SER 158/6
6 site apparatus for selective extraction of solid and semi-liquid samples using the Randall technique. A significant reduction in extraction time and solvent recovery is achieved. Reduction in extraction time. Solvent recovery above 90%.
Complete with
Grey and green gaskets 3 each, extraction cups, extraction cup holder, extraction thimbles 25 each, boiling stones, reagent bottles and operating/methods manual.